Home > Consulting Services
Consulting Services | Fire-Resistive Duct Inspection Services
Firestop Inspection Service
Fire-Resistive Duct Inspection Services
Explosion Simulation Analysis Calculation
Building Explosion Venting Area Calculation
BESS Explosion Venting Area Calculation
Dust Explosion Venting Area Calculation
Dust Explosion Testing and Analysis
Dust Hazard Analysis
-
Fire-Resistive Duct Inspection Services
International Standards · Accredited Certification · Safety Assurance
Liansuo Construction Technology Co., Ltd. provides professional on-site inspection services for fire-resistive duct systems to ensure building ventilation systems maintain fire-resistance integrity under fire conditions, preventing the spread of flames and smoke to safeguard life safety and protect property. Services are conducted in accordance with ISO/IEC 17020 and recognized under IAS AC98 accreditation, with all inspectors authorized under international standards.
-
Reference Standards
ASTM E3385Standard Practice for On-site Inspection of Fire Resistive Duct Systems UL 2221Standard for Tests of Fire Resistive Grease Duct Enclosure Assemblies ASTM E2336Test Methods for Fire Resistive Grease Duct Enclosure Systems ASTM E2816 Test Methods for Fire Resistive Metallic HVAC Duct Systems ISO 6944-1Fire Containment – Elements of Building Construction – Part 1: Ventilation Ducts
-
Scope of Inspection
Grease Duct SystemsEnsuring commercial kitchen exhaust ducts comply with fire-protection requirements HVAC Air Duct SystemsVerifying ductwork integrity and installation quality across fire compartments Hazardous Exhaust SystemsSpecialized inspections for chemical, laboratory, and energy sector ventilation systems
-
Inspection Procedure
一、Preparation Stage Review technical documents and listed product data Verify materials and components (steel thickness, fireproof coatings, reinforcement, etc.) Develop on-site inspection plan 二、Inspection Process & Key Focus Areas Duct Construction: Materials, thickness, seams, and airflow requirements Joints and Connections: Flange types, spacing, and assembly methods Reinforcement: Dimensions and spacing of reinforcement rods Fire Protection System: Fire rating, material thickness, and density compliance Supports and Hangers: Type, spacing, and load-bearing capacity Access Doors: Construction and fire-protection measures (if applicable) 三、Reporting & Re-Inspection Documentation: Record all non-conformities in inspection checklist Reporting: Issue inspection reports to contractors and clients Corrective Action & Re-Inspection: Follow-up inspections to confirm compliance with design listings and standards
-
Deliverables
Work Instruction Fire-Resistive Duct Inspection Checklist Inspection Report
Key Advantages
-
International Recognition
Fully compliant with ISO/IEC 17020 and
IAS AC98 accreditation requirements -
Authoritative Oversight
Inspectors authorized
under international standards -
Traceable Process
Comprehensive documentation
through checklists, images, and reports -
Risk Mitigation
Helping owners, contractors, and insurers
identify and rectify potential hazards
-
Consulting Services
Firestop Inspection Service
-
Consulting Services
Fire-Resistive Duct Inspection Services
-
Consulting Services
Explosion Simulation Analysis Calculation
-
Consulting Services
Building Explosion Venting Area Calculation
-
Consulting Services
BESS Explosion Venting Area Calculation
-
Consulting Services
Dust Explosion Venting Area Calculation
- 1
- 2